[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 239
Acceptance rate: 84.2
Rejection rate: 15.8
Average time to review: 97 days
Average time to publish: 26 days
..
:: Volume 13, Issue 4 (2-2025) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2025, 13(4): 13-22 Back to browse issues page
A simple optimization logic based on the parameters of the angle between voltage and current and the size of the terminal voltage to protect loss of excitation of synchronous generator
Mohammad sajjad Fatholahi * , Javad Moradi , Ali Rostami
Bisotun electricity Production Management Company
Abstract:   (15 Views)
In this study, by using two variables of the angle between voltage and current (θsg) and terminal voltage (Vsg) in a precise combinational logic, a new protection method is presented to detect the excitation loss of a synchronous generator. In this structure, the changes in θsg of the machine are continuously monitored and if it becomes positive, the changes in the Vsg parameter are examined. In this situation, if the amplitude of Vsg is greater than 0.95 per unit, it indicates the response of the machine control system and the normal operation of the machine will continue. However, if the magnitude of Vsg decreases and reaches a value less than 0.95 per unit, excitation loss occurs and the generator trip command is issued. The combined method proposed in this study has been evaluated in the MATLAB/Simulink (2017b) software environment during different scenarios of excitation loss and power system transients on the IEEE standard 39-bus system. The results of the simulations confirm the effectiveness of the proposed protection model. It should be noted that the superiority of the proposed method in terms of accuracy, speed, simplicity and implementation cost has also been compared with the impedance method.
Keywords: synchronous generator, loss of excitation protection, impedance relay, power angle, terminal voltage.
Full-Text [PDF 964 kb]   (22 Downloads)    
Type of Study: Research | Subject: Special
Received: 2024/11/30 | Accepted: 2025/02/1 | Published: 2025/02/28
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

fatholahi M S, moradi J, rostami A. A simple optimization logic based on the parameters of the angle between voltage and current and the size of the terminal voltage to protect loss of excitation of synchronous generator. تحقیقات نوین در سیستمهای قدرت هوشمند 2025; 13 (4) :13-22
URL: http://jeps.dezful.iau.ir/article-1-523-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 13, Issue 4 (2-2025) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4710