<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>محدودیت پایداری گذرا و هماهنگی حفاظتی در سیستم های توزیع دارای منابع پراکنده</title_fa>
	<title>Transient Stability Constraints and Protective Coordination in Distributed Resource Distribution Systems</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;یکی از موارد جدی مربوط به منابع پراکنده اثر خطاهای سیستم بر پایداری گذرای آنها است که به دلیل اینرسی پایین ژنراتورها&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;و عملکرد آهسته تجهیزات حفاظتی در سیستم&#8204;های توزیع، ناپایداری گذرا آن&#8204;ها کاملاً محتمل است. در این مقاله ابتدا رفتار دینامیکی منابع پراکنده بر روی خطاهای سیستم و سپس حساسیت منابع پراکنده به پارامترهای سیستم مورد بررسی قرار می&#8204;گیرد. در مرحله بعد، برخی از تنظیمات حفاظتی عملی توضیح داده می شود که از آن به عنوان رله&#8204;های نوعی ولتاژی استفاده می&#8204;شود و مزایا و معایب آنها ذکر شده است. در نهایت بر اساس نتایج به&amp;shy;دست آمده از تجزیه و تحلیل حساسیت، یک روش حفاظتی جدید برای حفظ پایداری منابع پراکنده در هنگام بروز خطا در شبکه توزیع پیشنهاد شده است. روش پیشنهادی، منابع پراکنده را مطابق یک رابطه زمان-توان اکتیو، از شبکه توزیع جدا می&#8204;کند. برای کلیه موارد مورد بررسی، زمان پاک&#8204;سازی خطا کمتر از زمان بحرانی پاک&#8204;سازی&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;است. همچنین نتایج شبیه&#8204;سازی&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;با&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;استفاده از نرم&#8204;افزار&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:9.0pt;&quot;&gt;Etap&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;، مقاوم بودن روش پیشنهادی را در برابر گذراهای سیستم نشان می&#8204;دهد&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>One of the serious issues related to these sources is the effect of system errors on their transient stability, which due to the low inertia of the generators and the slow performance of protection equipment in distribution systems, their transient instability is quite possible. In this paper, first the dynamic behavior of scattered sources on system errors and then the sensitivity of scattered sources to system parameters are investigated. In the next step, some practical protection settings are explained, which are used as voltage relays, and their advantages and disadvantages are mentioned. Finally, based on the results of sensitivity analysis, a new protection method has been proposed to maintain the stability of scattered resources in the event of an error in the distribution network. The proposed method separates scattered resources from the distribution network according to an active time-power relationship. For all cases under review, the error clearance time is less than the critical clearance time. The simulation results also show that the proposed method is resistant to system transitions.</abstract>
	<keyword_fa>تولیدات پراکنده کوچک, پایداری گذرا, زمان بحرانی پاک‌سازی</keyword_fa>
	<keyword>Small dispersed products, Transient stability, Critical clearance time</keyword>
	<start_page>35</start_page>
	<end_page>42</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-149-14&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Saeed </first_name>
	<middle_name></middle_name>
	<last_name>Adl</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عدل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saeed83adl@gmail.com</email>
	<code>10031947532846001761</code>
	<orcid>10031947532846001761</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق، واحد نجف آباد، دانشگاه آزاد اسلامی، نجف آباد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ghazanfar </first_name>
	<middle_name></middle_name>
	<last_name>Shahgholianzaban</last_name>
	<suffix></suffix>
	<first_name_fa>غضنفر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شاهقلیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shahgholian@iaun.ac.ir</email>
	<code>10031947532846001762</code>
	<orcid>10031947532846001762</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق، واحد نجف آباد، دانشگاه آزاد اسلامی، نجف آباد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Bahdor </first_name>
	<middle_name></middle_name>
	<last_name>Fani</last_name>
	<suffix></suffix>
	<first_name_fa>بهادر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>b.fani@pel.iaun.ac.ir</email>
	<code>10031947532846001763</code>
	<orcid>10031947532846001763</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق، واحد نجف آباد، دانشگاه آزاد اسلامی، نجف آباد، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
