<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>2</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر منبع ذخیره انرژی بر رفتار دینامیکی ژنراتور القایی دو سو تغذیه (DFIG)</title_fa>
	<title>The Impact of Energy Storage Tank on the Dynamic Behavior of Doubly Fed Induction Generator</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;چکیده: بهره برداری از نیروگاه بادی به دلیل ماهیت متغیر باد و شبکه دارای مشکلاتی میباشد. به دلیل عدد ثبات در سرعت وزش باد توان خروجی نیروگاه بادی متغیر می باشد. این عد قطعیت موجب کاهش کنترل پذیری نیروگاههای بادی میگردد. مشکل دیگر، جزیره ای شدن نیروگاه از شبکه سراسری بر اثر خطا میباشد. در این شرایط عد تناسب بین توان تولیدی و توان مورد نیاز می باشد، افدزایش DFIGi بار در بخش جدا شده سیستم، موجب دور شدن ولتاژ از مقدار مطلوب میشود. مشکل بعدی که مختص جریان مبدل سمت روتور در هنگا وقوع خطا در شبکه میباشد. در این مقاله به بررسی تاثیر منبع ذخیره انرژی بر رفتار نیروگاه در DFIG بادی با ژنراتور القایی از دو سو تغذیه در یک ریز شبکه پرداخته شده است. هدف این مقاله هموارسازی توان خروجی هنگام تغییر سرعت باد و حفاظت و جلوگیری از خروج آن از مدار با استفاده از منبع ذخیره انرژی باتری و ابر خازن با دو نوع اتصال مختلف می باشد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;Abstract:&lt;br&gt;
The operation of the wind power plant has problems due to the changing nature of wind and network. Because of the lack of stability in wind speed, wind power plant output is variable. This uncertainty is reduced controllability of wind power plants. Another problem, island power plants from the national grid by the fault. In this situation, an imbalance between power produced and power requirements in the isolated system, whereby away voltage of the desired value. The next problem is specific DFIG, increasing the current of rotor-side converter when the fault is in the network. In this paper, discussed the effect of energy storage tank on the behavior of wind power plant with Doubly Fed Induction Generator in a micro-grid. The purpose of this paper smoothing DFIG output power when changes in wind speed and protect and prevent it from leaving the circuit with the battery and super capacitor energy storage tank with two different connector type. Using simulation done by PSCAD shown that energy storage system has an important role in improving the dynamic stability of the grid and DFIG. Also compare two different control systems have been studied and shown that distributed ESS for internal changes of DFIG and complex ESS for the network faults have greater impact in improving the network.&lt;/p&gt;
</abstract>
	<keyword_fa>واژه های کلیدی: ژنراتور القایی از دو سو تغذیه, منبع ذخیره انرژی, جزیره ای شدن, هموار سازی توان, پایداری دینامیکی</keyword_fa>
	<keyword>Keywords: Doubly Fed Induction Generator, energy storage tank, an island, a smoothing power, dynamic stability</keyword>
	<start_page>47</start_page>
	<end_page>58</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-1-15&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyed Mostafa</first_name>
	<middle_name></middle_name>
	<last_name>Hosseini</last_name>
	<suffix></suffix>
	<first_name_fa>سید مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460035</code>
	<orcid>100319475328460035</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Iman</first_name>
	<middle_name></middle_name>
	<last_name>Pourfar</last_name>
	<suffix></suffix>
	<first_name_fa>ایمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پورفر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460036</code>
	<orcid>100319475328460036</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>