<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مروری بر پدیده شکست عایقی و تخلیه جزئی در پست گازی تحت شرایط برآمدگی هادی ، حفره عایق و ذره آزاد داخل محفظه</title_fa>
	<title>A Review on Insulation Failure and Partial Discharge in Gas Insulation Switchgear Considering Protrusion, Void and Free Particle</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>مقاله مروری</content_type_fa>
	<content_type>Review article</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;امروزه نقش انرژی الکتریکی در ایجاد رفاه اجتماعی و توسعه صنعتی جوامع بشری بر کسی پوشیده نیست. در سال&amp;shy; های اخیر قوانین جامع و کاملی برای تولید و عرضه این انرژی در بازار، تدوین و اجرا شده است. آنچه در این میان بیش از پیش نمود پیدا می&amp;shy; کند دغدغه مهندسان این عرصه برای تولید، انتقال و عرضه بی وقفه انرژی الکتریکی است. استفاده از تجهیزات کارآمد با قابلیت اطمینان بالا مهندسان را به کاربرد پست &amp;shy;های&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;عایق گازی در شبکه&amp;shy; های انتقال و توزیع سوق داده است. استفاده از عایق گازی ضمن کوچک &amp;shy;سازی ابعاد، موجب کاهش در هزینه &amp;shy;های حمل و نقل و زمان نصب و راه &amp;shy;اندازی این تجهیزات شده است. اگرچه تجهیزات عایق گازی به دلیل تکنولوژی ساخت و عایق&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;بندی خاص، نیازمند به حداقل تعمیرات هستند، اما با بالا رفتن عمر این تجهیزات، قابلیت اطمینان و کارکرد صحیح آنها کاهش می &amp;shy;یابد. نقصی که اغلب با گذشت زمان در این تجهیزات رخ می &amp;shy;دهد ، تخلیه&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;جزیی است. این رخداد نهایتا منجر به پدیده شکست عایقی می&amp;shy; شود که کمیتی مهم در ارزیابی شرایط عایق محسوب می &amp;shy;شود. در این مقاله مطالعات مربوط به عوامل موثر بر شکست عایقی پست&amp;shy; های عایق گازی و روش&amp;shy; های تشخیص به موقع آن، بر مبنای بهره&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;مندی از مقالات و تحقیقات موجود، انجام پذیرفته است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Today, the role of electric energy in creating social welfare and industrial development of human societies is not hidden from anyone. In recent years, comprehensive and complete laws have been compiled and implemented for the production and supply of this energy in the market. What shows up more than ever is the concern of engineers in this field for the production, transmission and uninterrupted supply of electrical energy. The use of efficient equipment with high reliability has led engineers to use gas insulated posts in transmission and distribution networks. The use of gas insulation, while reducing the dimensions, has caused a reduction in transportation costs and installation and commissioning time of this equipment. Although gas insulation equipment requires minimal repairs due to special manufacturing technology and insulation, but the reliability and proper functioning decreases as the life of this equipment increases. Often over time, partial drainage is a defect that occurs in this equipment. This event leads to insulation failure finally, which is an important quantity in assessing insulation conditions. The most common causes of partial discharge in gas substations are three factors: conductor electrode protrusion, Existence of void in insulation&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;and free particles suspended in gas pressurized&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;enclosure. In this paper, studies related to the factors affecting the insulation failure of GIS substations and its timely detection methods, based on the benefit of existing articles and research.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تخلیه جزئی, عایق گازی, شکست عایقی, ذرات آزاد, حفره عایقی</keyword_fa>
	<keyword>Partial discharge, Gas insulation, Insulation failure, Free particles, Insulation void</keyword>
	<start_page>29</start_page>
	<end_page>43</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-207-6&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Ghasemzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قاسم زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mr.ghasemzadeh@srbiau.ac.ir</email>
	<code>10031947532846002942</code>
	<orcid>10031947532846002942</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Power Engineering, Faculty of  Mechanics, Electrical and Computer, Science and Research Branch, Islamic Azad University,Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق قدرت و کنترل، دانشکده مکانیک، برق و کامپیوتر، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Faramarz </first_name>
	<middle_name></middle_name>
	<last_name>Faghihi</last_name>
	<suffix></suffix>
	<first_name_fa>فرامرز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فقیهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>faramarz.faghihi@srbiau.ac.ir</email>
	<code>10031947532846002943</code>
	<orcid>10031947532846002943</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical and Power Engineering, Faculty of  Mechanics, Electrical and Computer, Science and Research Branch, Islamic Azad University,Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق قدرت و کنترل، دانشکده مکانیک، برق و کامپیوتر، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Babak </first_name>
	<middle_name></middle_name>
	<last_name>Mozafari</last_name>
	<suffix></suffix>
	<first_name_fa>سید بابک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مظفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Mozafari@srbiau.ac.ir</email>
	<code>10031947532846002944</code>
	<orcid>10031947532846002944</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Power Engineering, Faculty of  Mechanics, Electrical and Computer, Science and Research Branch, Islamic Azad University,Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق قدرت و کنترل، دانشکده مکانیک، برق و کامپیوتر، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
