<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>یک مدل سه سطحی برای ارتقای تاب‌ آوری شبکه‌های توزیع فعال از طریق جایابی تیم‌های خدمات و واحدهای سیار</title_fa>
	<title>A Multi-Stage Framework for Resilience Enhancement of Active ‎Networks through Prepositioning of Crew Teams and Mobile ‎Emergency Unit</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:nasimYW;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;در سال های اخیر، میزان بلایای طبیعی به دلیل گرمایش زمین به میزان قابل توجهی افزایش یافته است. یکی از پرتکرارترین بلایای طبیعی طوفان است که امنیت سیستم&#8204;های توزیع را تهدید می&#8204;کند و در بسیاری از موارد منجر به قطعی&#8204;های عمده در شبکه می&#8204;شود. اقدامات پیشگیرانه در مورد هر اختلال و برنامه ریزی تولید در مرحله پس از رخداد دو اقدام مهم برای مقابله با شرایط اضطراری هستند. از این رو، این مقاله چارچوبی را برای افزایش انعطاف&#8204;پذیری سیستم توزیع ارائه می&#8204;کند که در آن علاوه بر اقدامات پیشگیرانه، زمان&#8204;بندی تولید با امکان پیکربندی مجدد شبکه انجام می&#8204;شود. چارچوب پیشنهادی به عنوان یک مسئله بهینه&#8204;سازی سه مرحله&#8204;ای، مدل&#8204;سازی می&#8204;شود که در آن پانل&#8204;های فتوولتائیک&amp;nbsp;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;PV&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;)، سیستم&#8204;های ذخیره انرژی الکتریکی&amp;nbsp;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;EES&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;) و اولویت بار در نظر گرفته می&#8204;شوند. در مرحله اول، قرار دادن بهینه کلیدهای کنترل از راه دور برای به حداقل رساندن انرژی تامین نشده&amp;nbsp;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;EENS&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;) انجام می&#8204;شود. لازم به ذکر است شبکه علاوه بر کلید&#8204;های اتوماتیک، مجهز به کلید&#8204;های دستی (کنترل در محل) است. در مرحله دوم پیش&#8204;فرض&#8204;سازی تیم&#8204;های خدمات (برای تغییر وضعیت کلید&#8204;های دستی) و ژنراتورهای اضطراری سیار&amp;nbsp;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MEG&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;) انجام می&#8204;شود. در نهایت در مرحله سوم، تعمیرات پس از رخداد انجام می&#8204;شود. مدل پیشنهادی بر روی یک سیستم توزیع 69 شینه پیاده&#8204;سازی شده است و نتایج نشان می&#8204;دهد که تغییر آرایش شبکه و اعزام &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MEG&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;ها به ترتیب منجر به کاهش 04/10% و 05/64% کاهش بار اجباری شده&#8204;اند. همچنین، نتایج تایید می&#8204;کنند که اجرای برنامه کنترل مستقیم بار&amp;nbsp;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;DLC&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;) منجر به کاهش 34/10% کاهش بار اجباری در بارهای بحرانی شده است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:nasimYW;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt; &lt;div id=&quot;edn5&quot;&gt;&lt;/div&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;color:#1d2228&quot;&gt;In recent years, the rate of natural disasters has increased significantly due to global warming. One of the most frequent natural disasters is the storm that threatens the security of distribution systems and in many cases leads to major outages in the network. Preventive measures in case of any disturbance and production planning in the post-event phase are two important measures to deal with&amp;nbsp;emergencies.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;color:#1d2228&quot;&gt;Therefore, this paper presents a framework for increasing the flexibility of the distribution system, where, in addition to preventive measures, production scheduling is performed with the possibility of network reconfiguration. The proposed framework is modeled as a three-stage optimization problem, where photovoltaic panels (PV), electric energy storage systems (EES), and load priority are considered. In the first step, the optimal placement of the remote control switches is performed to minimize the expected energy not served (EENS). It should be noted that in addition to automatic switches, the network is equipped with manual switches (on-site control). In the second stage, the prepositioning of crew teams (to alter the status of manual&amp;nbsp;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;color:#1d2228&quot;&gt;&amp;lrm;&lt;/span&gt;&lt;span style=&quot;color:#1d2228&quot;&gt;switches) is performed. Finally, in the third stage, repairs are done after the incident. The proposed model is implemented on a 69-bus distribution system. The results demonstrate that the dynamic topology and MEGs have reduced 10.04% and 64.05% of the forced load shedding, respectively. Also, the results confirm that implementing the direct load control (DLC) program has led to a 10.34% reduction in forced load shedding at the critical loads.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa>بازآرایی فیدر توزیع, ژنراتورهای اضطراری سیار, جایابی تیم خدمات, سیستم‌های ذخیره سازی انرژی الکتریکی, کنترل بار مستقیم</keyword_fa>
	<keyword>Distribution Feeder Reconfiguration, Mobile Emergency Generators, Crew Teams Allocation, Electrical Energy Storage, Direct Load Control, Fragility Function</keyword>
	<start_page>1</start_page>
	<end_page>19</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-307-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyed Mohammad Amin </first_name>
	<middle_name></middle_name>
	<last_name>Hashemifar</last_name>
	<suffix></suffix>
	<first_name_fa>محمد امین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohammadamin_hashemifar@yahoo.com</email>
	<code>10031947532846002205</code>
	<orcid>10031947532846002205</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Electrical Department, Dezful Branch, Islamic Azad University, Dezful, Iran</affiliation>
	<affiliation_fa>گروه برق، واحد دزفول، دانشگاه آزاد اسلامی، دزفول، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>, Mahmood </first_name>
	<middle_name></middle_name>
	<last_name>Joorabian</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جورابیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mjoorabian@yahoo.com</email>
	<code>10031947532846002206</code>
	<orcid>10031947532846002206</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Electrical Department, Faculty of Electrical Engineering, Ahvaz Shahid Chamran University, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه برق، دانشکده مهندسی برق ، دانشگاه شهید چمران اهواز، اهواز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Sadegh </first_name>
	<middle_name></middle_name>
	<last_name>Javadi </last_name>
	<suffix></suffix>
	<first_name_fa>محمد صادق</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جوادی اصطهباناتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>msjavadi@gmail.com</email>
	<code>10031947532846002207</code>
	<orcid>10031947532846002207</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Electrical Department, Shiraz Branch, Islamic Azad University, Shiraz, Iran</affiliation>
	<affiliation_fa>گروه برق، واحد شیراز، دانشگاه آزاد اسلامی، شیراز، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
