<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ﺑﻬﺒﻮد ﭘﺎﺳﺦ دﻳﻨﺎﻣﻴﻜﻰ و ﮔﺬر از وﻟﺘﺎژ ﭘﺎﻳﻴﻦ ﺗﻮرﺑﻴﻦ ﻫﺎی ﺑﺎدی ﺑﺎ اﺳﺘﻔﺎده از ﺳﻴﺴﺘﻢ ﺗﺮﻛﻴﺒﻰ ﺑﻬﺒﻮد دﻫﻨﺪه ﻛﻴﻔﻴﺖ ﺗﻮان وﻣﺤﺪودﺳﺎز ﺟﺮﻳﺎن ﺧﻄﺎ</title_fa>
	<title>improving the dynamic response and passing the low voltage of wind turbines by using a combined system to   improve the quality of power.</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 11pt;&quot;&gt;&lt;span style=&quot;direction: rtl;&quot;&gt;&lt;span style=&quot;unicode-bidi: embed;&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;توربین&amp;shy; های بادی مبتنی بر ژنراتور القایی از دو سو تغذیه (&lt;/span&gt;&lt;span dir=&quot;LTR&quot; new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;DFIG&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;) به خصوص در توان کم، در حین خطاهای سمت شبکه بسیار آسیب&amp;shy; پذیر هستند. در اکثر تحقیقات از یک کروبار برای حفاظت از مبدل سمت روتور در حین خطاهای شبکه استفاده می&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;شود . شبکه&amp;shy; های جدید نیازمند توربین&amp;shy; های بادی هستند که بتوانند در شرایط خطا متصل مانده و تامین ظرفیت تقاضا شده را به عهده بگیرند. در این مقاله یک سیستم حفاظتی جدید مبتنی بر محدودکننده جریان خطای مقاومتی با قابلیت سوئیچینگ برای محافظت از توربین&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;های بادی مبتنی بر ژنراتور القایی از دو سو تغذیه و توربین بادی مبتنی بر ژنراتور سنکرون در حین خطاهای سمت شبکه معرفی کرده است. محدود کننده پیشنهادی در سمت &lt;/span&gt;&lt;span dir=&quot;LTR&quot; new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;DC&lt;/span&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;مبدل سمت روتور استفاده می&amp;shy; شود. سیستم مذکور مشکلات کروبار را حل می &amp;shy;کند و عوارض بعدی را در سیستم حذف می&amp;shy; کند. محدودکننده&amp;shy; ی پیشنهادی هیچ تاثیر قابل توجهی بر عملکرد کلی شبکه در حین عملکرد نرمال ندارد. هر زمان که خطا، خواه متقارن یا نامتقارن، رخ دهد، نه تنها جریان اضافی روتور را محدود می &amp;shy;&amp;shy;کند، بلکه از شتاب سرعت روتور جلوگیری می&amp;shy; کند و نوسانات گشتاور بالا را حتی در هنگام ولتاژ شبکه صفر محدود می &amp;shy;کند، نتایج شبیه سازی&lt;/span&gt;&lt;b&gt; &lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 12pt;&quot;&gt;در نرم &amp;shy;افزار متلب مدل&amp;shy; سازی و &amp;nbsp;عملکرد محدودکننده را در حفاظت از توربین بادی در شرایط خطای شبکه تایید می&amp;shy; کند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 11pt;&quot;&gt;&lt;span style=&quot;tab-stops: 14.2pt 21.3pt 169.5pt;&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;Induction generator based wind turbines are very vulnerable to malnutrition, especially in low power, during grid side faults.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;In most studies, a finger is used to protect the rotor - side converter during network faults.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;New networks require wind turbines that can stay connected in fault conditions and provide the requested capacity.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;In this paper, a new control system based on ounding fault current has been introduced to protect the two mal nourished induction generator - based wind turbines and the bounding generator - based wind turbine during grid - side faults. The proposed limiting is used on the DC side of the rotor - side converter.the mentioned system solves the problems and eliminates the following problems in the system. &lt;/span&gt;&lt;/span&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;The proposed restriction has no significant effect on overall network performance during normal operation.&lt;/span&gt; &lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;Whenever a fault occurs, whether symmetric or asymmetric, it not only limits the over current of the rotor but also prevents the acceleration of the rotor speed and limits high torque fluctuations even during the zero grid voltage, the simulation results confirm the limiting performance in protecting the wind turbine in grid fault conditions.&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa>PMSG, DFIG, خطاهای شبکه, محدودکننده جریان خطای مقاومتی با قابلیت سوئیچینگ (SRFCL)</keyword_fa>
	<keyword>PMSG – DFIG - Network Errors-Srfcl.</keyword>
	<start_page>31</start_page>
	<end_page>52</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-319-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Shayan</first_name>
	<middle_name></middle_name>
	<last_name>Nadari</last_name>
	<suffix></suffix>
	<first_name_fa>شایان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نادری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nadarishayan@yahoo.com</email>
	<code>10031947532846003104</code>
	<orcid>10031947532846003104</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering Ahvaz Branch, Islamic Azad University, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق، واحد اهواز، دانشگاه آزاد اسلامی، اهواز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali Reza </first_name>
	<middle_name></middle_name>
	<last_name>Tavakoli</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>توکلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aa.tavakoli@iau.ac.ir</email>
	<code>10031947532846003105</code>
	<orcid>10031947532846003105</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering Ahvaz Branch, Islamic Azad University, Ahvaz, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق، واحد اهواز، دانشگاه آزاد اسلامی، اهواز، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
