<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Novel Researches on Smart Power Systems</title>
<title_fa>نشریه علمی-تخصصی تحقیقات نوین در سیستمهای قدرت هوشمند</title_fa>
<short_title>تحقیقات نوین در سیستمهای قدرت هوشمند</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeps.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2468</journal_id_issn>
<journal_id_issn_online>2322-2468</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>1</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مکان‌یابی و تعیین تعداد بهینه واحدهای اندازه‌گیری فازوری (PMU) جهت مشاهده‌پذیری سیستم‌های قدرت</title_fa>
	<title>Placement and Determining the Optimal Number of Phasor Measurement Units (PMU) for Power Systems Observability</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;امروزه در شبکه&#8204;های قدرت به&#8204;دلایل مختلف از جمله خطی&#8204;سازی معادلات تخمین حالت و بهبود سرعت سیستم&#8204;های کنترلی و حفاظتی از واحد&#8204;های اندازه&#8204;گیری فازوری &amp;nbsp;استفاده می&#8204;شود. بهینه&#8204;سازی تعداد و مکان این تجهیزات با توجه به قیمت بالای آن&#8204;ها از اهمیت ویژه&#8204;ای برخوردار است. عوامل تأثیر&#8204;گذار در مکان و تعداد بهینه توپولوژی شبکه، شین&#8204;های تزریق صفر و اندازه&#8204;گیرهای معمول مورد استفاده در شبکه&#8204;های قدرت می&#8204;باشند. در این مقاله تابع هدفی بر&#8204;اساس برنامه&#8204;ریزی خطی عدد صحیح جهت تعیین تعداد و مکان بهینه&#8204;ی به&#8204;منظور مشاهده&#8204;پذیری کامل سیستم قدرت ارائه خواهد شد. همچنین تأثیر شین&#8204;های تزریق صفر و اندازه&#8204;گیرهای معمول در سیستم&#8204;های قدرت بر روی تابع هدف مورد بررسی قرار می&#8204;گیرد. شبیه&#8204;سازی&#8204;ها با استفاده از نرم&#8204;افزار بر روی شبکه&#8204;های استاندارد 9، 14، 30، 39، 57 و 118 شینه انجام شده و در مطالعه شبکه 14 شینه نحوه&#8204;ی تشکیل پارامترهای تابع هدف مورد بررسی قرار گرفته است. نتایج نشان می&#8204;دهد که اعمال قیود مربوط به شین&#8204;های تزریق صفر و همچنین قیود مربوط به سیستم در مسئله مکان&#8204;یابی بهینه موجب کاهش تعداد مورد نیاز برای مشاهده&#8204;پذیری کامل سیستم قدرت می&#8204;شود که باعث صرفه&#8204;جویی در هزینه خواهد شد.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p class=&quot;Abstract&quot; style=&quot;text-indent: 0in; line-height: 115%; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 11pt; line-height: 115%;&quot;&gt;Nowadays, phasor measurement units are used in power networks for different purposes, such as Linearization of state estimation equations and speed improvement of controlling and protecting systems. Optimization of position and number of these equipments is considerably important because of their high costs. Effective parameters on position and number of PMUs optimization are: Network topology, zero injection buses and commonly used measurement devices in power networks. In this paper an objective function based on integer linear programming (ILP) is presented to determine the number and optimized position of PMUs, in order to complete observability of power systems. The effect of zero injection buses and prevalent measurement devices on objective function in power networks is evaluated. Simulation results are presented for the IEEE 9, 14, 30, 39, 57 and 118 buses systems. The optimization method is numerically solved using MATLAB software environment and formation of parameters of objective function in IEEE 14 buses network has been studied.&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size: 11pt; line-height: 115%;&quot;&gt;&lt;!--stripped--&gt;&lt;!--stripped--&gt;&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>واحدهای اندازه‌گیری فازوری, مکان‌یابی بهینه, مشاهده‌پذیری سیستم قدرت</keyword_fa>
	<keyword>ILP, PMU, Network, Optimization</keyword>
	<start_page>59</start_page>
	<end_page>70</end_page>
	<web_url>http://jeps.dezful.iau.ir/browse.php?a_code=A-10-1-34&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>B.</first_name>
	<middle_name></middle_name>
	<last_name>Moaref</last_name>
	<suffix></suffix>
	<first_name_fa>بهروز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>معرف</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460084</code>
	<orcid>100319475328460084</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H.</first_name>
	<middle_name></middle_name>
	<last_name>Barati</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>براتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460085</code>
	<orcid>100319475328460085</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A. H. </first_name>
	<middle_name></middle_name>
	<last_name>Rahmani</last_name>
	<suffix></suffix>
	<first_name_fa>امیرحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460086</code>
	<orcid>100319475328460086</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
