[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 271
Acceptance rate: 84.1
Rejection rate: 15.9
Average time to review: 96 days
Average time to publish: 26 days
..
:: ::
Back to the articles list Back to browse issues page
Minimizing Losses and Improving Voltage Profile in Standard and Real Electric Power Distribution Networks Using Reconfiguration and Distributed Generation
Fereshteh Mirzaeian1 , Hassan Barati *2
1- Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran, Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran
2- Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran , hassanbarati@iau.ac.ir
Abstract:   (6 Views)
Energy losses in distribution networks not only increase costs but also lead to a reduction in system efficiency and a decline in service quality. Furthermore, voltage profile is a crucial criterion for network performance, directly affecting power quality and the safety of consumer equipment. This paper proposes a novel method to solve the network reconfiguration optimization problem in the presence of Distributed Generation (DG), with the aim of reducing active power losses and improving the voltage profile in the distribution system. For this purpose, the Harmony Search Algorithm (HSA) meta-heuristic algorithm is simultaneously employed for network reconfiguration and identifying optimal locations for installing DG units in the distribution network. Additionally, sensitivity analysis has been utilized to determine the optimal installation sites for DG. Various scenarios for DG placement and network reconfiguration optimization have been investigated. To evaluate the performance of the proposed method, voltage constraints and branch current capacities have been incorporated into the objective function. The method has been applied to 33-bus and 69-bus radial distribution systems, as well as an 8-bus real distribution network in the Khuzestan Electric Power Distribution Company, demonstrating its suitable performance, and the obtained results have been favorable.

 
Keywords: Distribution system reconfiguration, power loss, distributed generation, voltage profile, actual test system, Harmony Search Algorithm
     
Type of Study: Research | Subject: Special
Received: 2025/10/2 | Accepted: 2026/10/2
* Corresponding Author Address: Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Back to the articles list Back to browse issues page
تحقیقات نوین در سیستم های قدرت هوشمند Journal of Novel Researches on Smart Power Systems
Persian site map - English site map - Created in 0.19 seconds with 39 queries by YEKTAWEB 4774