[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 234
Acceptance rate: 84.3
Rejection rate: 15.7
Average time to review: 98 days
Average time to publish: 26 days
..
:: Volume 8, Issue 3 (12-2019) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2019, 8(3): 37-51 Back to browse issues page
Direct power control simultaneously in the rotor side converter and grid side converter of DFIG for wind turbines with elimination of network current harmonics
Seyed Ne'matollah Hosseini Mousavi , Hassan Barati *
Dezful Branch, Islamic Azad University, Dezful, Iran
Abstract:   (1187 Views)
In this paper, direct power control (DPC) was used for active and reactive power control of DFIG in constant speed reference and variable turbine speed reference based on the optimal power curve. On the other hand, wide application of nonlinear loads in power networks has caused problems such as high current harmonics. Non-linear loads act like harmonic current sources and inject harmonic currents into the supply network. The presence of harmonics in the network causes the harmonic voltage drop and causes other consumers to receive distorted supply voltage, which may cause overheating of power factor correction capacitors, motors, transformers and cables, and mal-operation of some protection devices. Since DFIG is responsible for injection of active and reactive power to the network, it is possible to compensate for the fluctuation of power due to nonlinear loads in the network by proper power injection. Therefore, in this paper, direct power control is implemented to control the power of DFIG, and also to reduce the network current harmonics in the presence of nonlinear loads by using the proper control methods through the rotor side converter and grid side convertors. In this regard, the Matlab/Simulink software is used to simulate a system including a DFIG-based wind power unit and the results are analyzed and compared in different scenarios. The results indicate that accurate and fast control of the DFIG power is along with a significant reduction of network current harmonics.
Keywords: wind turbine, DFIG, Direct Power Control, optimum Power Curve, network current harmonics
Full-Text [PDF 1761 kb]   (851 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2019/10/2 | Accepted: 2019/12/11 | Published: 2019/12/11
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hosseini Mousavi S N, Barati H. Direct power control simultaneously in the rotor side converter and grid side converter of DFIG for wind turbines with elimination of network current harmonics. تحقیقات نوین در سیستمهای قدرت هوشمند 2019; 8 (3) :37-51
URL: http://jeps.dezful.iau.ir/article-1-229-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 8, Issue 3 (12-2019) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4700