تحقیقات نوین در سیستمهای قدرت هوشمند 2020, 8(4): 45-54 Back to browse issues page
Help substation dynamic mode when setting up large induction motor using static power reactive compensators
Farhad Daneshi , Ali Darvishi Falehi *
Department of Electrical Engineering, Shadegan Branch, Islamic Azad University, Shadegan, Iran
Abstract:   (1081 Views)
Static reactive power compensators (SVCs) have been widely used to improve voltage and power factor ratios in factory and industrial substations. Therefore, these two functions are independent of each other and it is necessary to improve the power factor in order to regulate the voltage. In this paper, the new SVC startup method for induction motors is suggested. In this method, the amount of reactive power is precisely and controllable according to the load requirements. A hybrid controller includes slow suspension control and rapid voltage control that gives the SVC the ability to achieve power factor correction and creates a constant voltage characteristic during the start of the large induction motor. An ideal compensation method is recommended for both optimal voltage regulation and power factor correction. A case study on the operation of a large 1.4MW induction motor is presented with several startup methods. The comparative study is done by simulation with MATLAB software for different startup cases. Finally, the results of safe and reliable performance simulation guarantee the proposed method for effective design of operational posts.
Keywords: Compensator, static compensators reactive power, induction motor, dynamic behavior.
Full-Text [PDF 1500 kb]   (526 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2020/01/11 | Accepted: 2020/03/15 | Published: 2020/05/12
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Daneshi F, Darvishi Falehi A. Help substation dynamic mode when setting up large induction motor using static power reactive compensators. تحقیقات نوین در سیستمهای قدرت هوشمند 2020; 8 (4) :45-54
URL: http://jeps.dezful.iau.ir/article-1-252-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 8, Issue 4 (2-2020) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4700