[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 234
Acceptance rate: 84.3
Rejection rate: 15.7
Average time to review: 98 days
Average time to publish: 26 days
..
:: Volume 9, Issue 1 (5-2020) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2020, 9(1): 47-55 Back to browse issues page
Influence of Current Sensor Technology on Current-Transformer Saturation in Distance Protection
Javad Eshraghi , Sepehr Soltani *
Departement of Electrical Engineering, Sabzevar Branch, Islamic Azad University, Sabzevar, Iran
Abstract:   (803 Views)
Today, the distance relay is widely used in transmission and over-distribution lines. Due to the zoning of the protection zone, the distance relay provides a simple and economical way to detect faults. The current-transformer saturation in high-voltage substation causes faults in the protection zones of the distance relay and the operating time of the distance relay zones is not correct when an error occurs. To solve this problem, this article suggests optical current transformers. Initially, the simulated optical current transformer model was presented, the optical current transformer was compared with the conventional current transformer in IEEE 9 bus network substation using DIGSILENT software. The results show that the proposed optical current transformer covers well the faults of relay distance caused by the saturation of the normal current transformer.
Keywords: Current Transformer, Distance Relay, Fiber-Optic Current Sensor
Full-Text [PDF 1184 kb]   (859 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2020/04/13 | Accepted: 2020/06/19 | Published: 2020/06/19
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Eshraghi J, Soltani S. Influence of Current Sensor Technology on Current-Transformer Saturation in Distance Protection. تحقیقات نوین در سیستمهای قدرت هوشمند 2020; 9 (1) :47-55
URL: http://jeps.dezful.iau.ir/article-1-267-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 1 (5-2020) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.07 seconds with 39 queries by YEKTAWEB 4700