[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 234
Acceptance rate: 84.3
Rejection rate: 15.7
Average time to review: 98 days
Average time to publish: 26 days
..
:: Volume 10, Issue 3 (12-2021) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2021, 10(3): 53-65 Back to browse issues page
Coordination of distance relays and directional over current with optimal injection of DG capacity using smart method
Mohammadreza Aminian , Mehdi Jafari Shahbazzadeh * , Mahdiyeh Eslami
Department of Electrical Engineering, Kerman Branch, Islamic Azad University, Kerman, Iran
Abstract:   (394 Views)
One of the most applicable relays in protecting the power system is distance and overcurrent relays. In transmission and distribution networks, protection is usually performed by distance protection, and overcurrent protection is used as a backup for distance protection. In the present study, a new approach was provided to coordinate distance and overcurrent relays using pickup current, time adjustment coefficient, and overcurrent relay characteristics to delay these relays as backup for distance relays. It is possible to adjust the second zone of the distance relays' operating time with a fixed and normal value using instantaneous operation relays with changes in coordination constraints. In the proposed method, the coordination problem was solved using GA algorithm. A protection coordination index is then provided to evaluate distributed generation sources' impact on the protection coordination of distance and overcurrent relays. A new method was proposed to obtain the maximum injection capacity under coordination constraints using MATLAB and DIGSILENT software's parallel performance. The proposed method was implemented in IEEE 9 and 39 bus sample networks. Finally, the obtained results were compared and evaluated.
Keywords: Protection Coordination, Directional overcurrent relay, disperse production resources, protection coordination index
Full-Text [PDF 1138 kb]   (142 Downloads)    
Type of Study: Research | Subject: Special
Received: 2021/09/4 | Accepted: 2021/11/26 | Published: 2021/12/8
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Aminian M, Jafari Shahbazzadeh M, Eslami M. Coordination of distance relays and directional over current with optimal injection of DG capacity using smart method. تحقیقات نوین در سیستمهای قدرت هوشمند 2021; 10 (3) :53-65
URL: http://jeps.dezful.iau.ir/article-1-368-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 10, Issue 3 (12-2021) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4700