:: Volume 11, Issue 1 (5-2022) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2022, 11(1): 35-45 Back to browse issues page
Investigation of the High Frequency Effects of Lightning Impulse on the Voltage of Different Points of Grounding Grid with Considering Power Transformer
Mohammad Talebzadeh , Alireza Setayeshmehr * , Hasan Barati
Faculty of Electrical and Computer Engineering, Jundi Shapur University of Technology, Dezful, Iran
Abstract:   (139 Views)
In general, the earth and its connections are modeled using an impedance including resistor, capacitor, and inductor. Since the connection point resistance is due to the electrical resistivity of the connection point to the earth, in this the studied in the network area. The values of the capacitance and inductor are also considered for studied at high frequency and related to lightning and switching. In this paper, the effect of the earth impedance and the meshing network on the earth point voltage of the power substations during lightning is studied. Therefore, first, the electrical model of the soil is obtained according to the calculations and the electrical model of the meshing network is connected to each other through copper wires in model. Eventually, the electrical model of the electrodes ground in modeled is the earth network around and the corners. By applying a voltage lines connected to the transformers by lightning, the earth point voltage value is calculated and drawn at different points of meshing network. All of these stages are simulated in MATLAB/Simulink. The results show a change at ground point voltage level due to apply lighting at different points of the meshing network. The amount of impedance measured up to medium frequencies will be constant and at high frequencies up to 1 MHz will be incremental. All measurements and calculations have been done considering the power transformer and its connection to the meshing network. The aim of measuring the voltage of different points on the ground is to consider the power transformer, which is designed for better regulation of the protective relays, accurate measurement of the ground impedance.
Keywords: Earth Impedance, Lightning, Impulse, Meshing
Full-Text [PDF 1113 kb]   (90 Downloads)    
Type of Study: Research | Subject: Special
Received: 2022/02/14 | Accepted: 2022/04/25 | Published: 2022/04/25
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Talebzadeh M, Setayeshmehr A, Barati H. Investigation of the High Frequency Effects of Lightning Impulse on the Voltage of Different Points of Grounding Grid with Considering Power Transformer. تحقیقات نوین در سیستمهای قدرت هوشمند 2022; 11 (1) :35-45
URL: http://jeps.dezful.iau.ir/article-1-397-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 11, Issue 1 (5-2022) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4700