[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 234
Acceptance rate: 84.3
Rejection rate: 15.7
Average time to review: 98 days
Average time to publish: 26 days
..
:: Volume 12, Issue 1 (5-2023) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2023, 12(1): 9-18 Back to browse issues page
Detecting and Fault Ride-Through (FRT) in the power system with wind, solar and electric energy storage renewable sources
Ehsan Akbari *
- Department of Electrical Engineering, Mazandaran University of Science and Technology, Babol, Iran
Abstract:   (756 Views)
The proposed structure of this article is a hybrid wind-solar-storage system with fault tolerance that reduces output power fluctuations and voltage drop in the system caused by faults. In the proposed topology, the solar system is connected to the DFIG through a DC-DC converter, thus eliminating the need for a special inverter for the solar system and reducing the cost. The power management in this system is done using the converters of the rotor section and the DC-DC controller related to the DC link using the phased method, which is why there is no need to use a compensator in the system. The better the control system works, the better and sooner the fault detection and compensation will be done, and this will prevent the system from being damaged and unstable, and will not cause serious damage to the system. In this thesis, the simulation results for two scenarios were investigated. In both scenarios, the active power decreases during 0.3 seconds when a sudden voltage drop occurs, but the reactive power increases due to the compensation of the created error. With the occurrence of an error and a sudden voltage drop in the system, the wind turbine has not reached an unstable state and a sudden increase in torque has not occurred, and the control system has worked well. Therefore, in this research, the proposed system was able to perform fault detection and voltage drop compensation through DC link voltage stabilization and reactive power injection in order to improve the voltage drop. It should be noted that all simulations were done in MATLAB/Simulink software.
Keywords: Fault Ride-Through (FRT), Renewable Energy, wind, solar, electrical energy storage
Full-Text [PDF 1666 kb]   (246 Downloads)    
Type of Study: Research | Subject: Special
Received: 2023/03/25 | Accepted: 2023/05/23 | Published: 2023/05/31
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Akbari E. Detecting and Fault Ride-Through (FRT) in the power system with wind, solar and electric energy storage renewable sources. تحقیقات نوین در سیستمهای قدرت هوشمند 2023; 12 (1) :9-18
URL: http://jeps.dezful.iau.ir/article-1-456-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 1 (5-2023) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4700