[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Overall Journal Statistics
Published articles: 234
Acceptance rate: 84.3
Rejection rate: 15.7
Average time to review: 98 days
Average time to publish: 26 days
..
:: Volume 13, Issue 3 (11-2024) ::
تحقیقات نوین در سیستمهای قدرت هوشمند 2024, 13(3): 31-52 Back to browse issues page
improving the dynamic response and passing the low voltage of wind turbines by using a combined system to improve the quality of power.
Shayan Nadari , Ali Reza Tavakoli *
Department of Electrical Engineering Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
Abstract:   (58 Views)
Induction generator based wind turbines are very vulnerable to malnutrition, especially in low power, during grid side faults. In most studies, a finger is used to protect the rotor - side converter during network faults. New networks require wind turbines that can stay connected in fault conditions and provide the requested capacity. In this paper, a new control system based on ounding fault current has been introduced to protect the two mal nourished induction generator - based wind turbines and the bounding generator - based wind turbine during grid - side faults. The proposed limiting is used on the DC side of the rotor - side converter.the mentioned system solves the problems and eliminates the following problems in the system. The proposed restriction has no significant effect on overall network performance during normal operation. Whenever a fault occurs, whether symmetric or asymmetric, it not only limits the over current of the rotor but also prevents the acceleration of the rotor speed and limits high torque fluctuations even during the zero grid voltage, the simulation results confirm the limiting performance in protecting the wind turbine in grid fault conditions.

 
Keywords: PMSG – DFIG - Network Errors-Srfcl.
Full-Text [PDF 2452 kb]   (21 Downloads)    
Type of Study: Research | Subject: Special
Received: 2024/05/14 | Accepted: 2024/10/12 | Published: 2024/11/30
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nadari S, Tavakoli A R. improving the dynamic response and passing the low voltage of wind turbines by using a combined system to improve the quality of power.. تحقیقات نوین در سیستمهای قدرت هوشمند 2024; 13 (3) :31-52
URL: http://jeps.dezful.iau.ir/article-1-505-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 13, Issue 3 (11-2024) Back to browse issues page
تحقیقات نوین در برق Journal of Novel Researches on Electrical Power
Persian site map - English site map - Created in 0.08 seconds with 39 queries by YEKTAWEB 4700